Description
BMV 600HS: 70 to 350VDC voltage range
The essential function of a battery monitor is to calculate ampere-hours consumed and the state of
charge of a battery. Ampere-hours consumed is calculated by integrating the current flowing in or out of
the battery. In case of a constant current, this integration is equivalent to current multiplied by time. A
discharge current of 10A during 2 hours, for example, amounts to 20Ah consumed. All our battery
monitors are based on a powerful microprocessor, programmed with the algorithms needed for
precision monitoring.
Standard information and alarms
- Battery voltage (V).
- Battery charge/discharge current (A).
- Ampere-hours consumed (Ah).
- State of charge (%).
- Time to go at the current rate of discharge.
- Visual and audible alarm: over- and under voltage, and/or battery discharged.
- Programmable alarm or generator start relay.
BMV 600HS: 70 to 350VDC voltage range
No prescaler needed. Note: suitable for systems with grounded minus only (battery monitor is not
isolated from shunt).
Specification
- Power supply voltage range -70 – 350 VDC
- Current draw, back light off - < 4 mA
- Input voltage range (VDC) - 70 – 350 VDC
- Battery capacity (Ah) 20 – 9.999
- Operating temperature range -20 +50°C (0 - 120°F)
- Measures voltage of second battery: Yes
- Communication port : Yes
- Potential free contacts: 60V/1A (N/O)